Zeror.ai Error Codes Fronius Err: 38.2

Fronius Err: 38.2

Brand: FroniusModel: Kaynak Makinesi — TPS/i / TransPuls SynergicError code: Err: 38.2

What the Fault Means

Gaz akış miktarı yetersiz - minimum gaz debisi altında

Likely causes

  • Gaz regülatörü yanlış ayarlı
  • Gaz hortumunda kısılma var
  • Solenoid valf tam açılmıyor

Solution and Safe First Checks

  1. Gaz debisini 10-15 L/dak'ya ayarlayın
  2. Hortum bükülmelerini düzeltin
  3. Solenoid valfi temizleyin veya değiştirin

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Fronius error codes

Source: the Zeror.ai industrial fault database and Fronius technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.

Fronius Err: 38.2 · Zeror.ai