Zeror.ai Error Codes KUKA KRC2-2959

KUKA KRC2-2959

Brand: KUKAModel: KRC2Error code: KRC2-2959

What the Fault Means

Remedy

Likely causes

  • In the file “$OPTION.DAT”, the phase voltage monitoring is configured by
  • “$PHASE_MONITORING=TRUE”, although either the KPS software version is lower than 11 or there is no “DSE--IBS--C33” available.

Solution and Safe First Checks

  1. In the file “$OPTION.DAT”, set the phase voltage monitoring to
  2. “$PHASE_MONITORING=FALSE”, or satisfy the necessary hardware
  3. prerequisites (KPS software version 11 or higher and “DSE--IBS--C33”).

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related KUKA error codes

Source: the Zeror.ai industrial fault database and KUKA technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.

KUKA KRC2-2959 · Zeror.ai