Zeror.ai Error Codes Siemens A01358

Siemens A01358

Brand: SiemensModel: SINAMICS G120 CU250S2Error code: A01358

What the Fault Means

Alarm: Topology: Line termination not available

Likely causes

  • At least one line with distributed drives is not terminated
  • The last participant on the line must be terminated with a line termination connector
  • This therefore ensures the degree of protection of the distributed drives
  • Alarm value (r2124, interpret hexadecimal): zzyyxx hex: zz = connection number of the distributed drive where there is no terminating connector yy = component number xx = CU connection number

Solution and Safe First Checks

  1. Install the line terminating connector for the last distributed drive.

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Siemens error codes

Source: the Zeror.ai industrial fault database and Siemens technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.