Zeror.ai Error Codes Siemens A01382

Siemens A01382

Brand: SiemensModel: SINAMICS G120 CU250S2Error code: A01382

What the Fault Means

Alarm: Topology: Sensor Module incorrectly inserted

Likely causes

  • The topology comparison has detected a Sensor Module in the actual topology that has been incorrectly inserted with respect to the target technology
  • Alarm value (r2124, interpret hexadecimal): ddccbbaa hex: dd = connection number (%4) cc = component number (%3) bb = component class (% 2) aa = component number of the incorrectly inserted component (% 1) Note: The component is described in dd, cc and bb, where the component involved is incorrectly inserted
  • Component class and connection number are described in F01375
  • The drive system is no longer booted

Solution and Safe First Checks

  1. insert the components involved at the right connection (correct the actual topology).
  2. adapt the project/parameterization in the commissioning software (correct the target topology).
  3. automatically remove the topology error (p9904).

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Siemens error codes

Source: the Zeror.ai industrial fault database and Siemens technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.

Siemens A01382 · Zeror.ai