Zeror.ai Error Codes Siemens F07983

Siemens F07983

Brand: SiemensModel: SINAMICS G120 CU250S2Error code: F07983

What the Fault Means

Fault: Drive: Rotating measurement saturation characteristic

Likely causes

  • A fault has occurred while determining the saturation characteristic
  • Fault value (r0949, interpret decimal): 1: The speed did not reach a steady-state condition
  • 2: The rotor flux did not reach a steady-state condition
  • 3: The adaptation circuit did not reach a steady-state condition

Solution and Safe First Checks

  1. the total drive moment of inertia is far higher than that of the motor (p0341, p0342).
  2. increase the measuring speed (p1961) and repeat the measurement.
  3. check the motor parameters (rating plate data). After the change: Calculate p0340 = 3.
  4. check the moment of inertia (p0341, p0342). After the change: Calculate p0340 = 3.
  5. carry out a motor data identification routine (p1910).
  6. if required, reduce the dynamic factor (p1967 < 25 %).

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Siemens error codes

Source: the Zeror.ai industrial fault database and Siemens technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.

Siemens F07983 · Zeror.ai