Zeror.ai Error Codes Siemens F30681

Siemens F30681

Brand: SiemensModel: SINAMICS G120 CU250S2Error code: F30681

What the Fault Means

Fault: SI Motion P1: Incorrect parameter value

Likely causes

  • The parameter cannot be parameterized with this value
  • Note: This message does not result in a safety stop response
  • Fault value (r0949, interpret decimal): yyyyxxxx dec: yyyy = supplementary information, xxxx = parameter yyyy = 0: No information available
  • xxxx = 9301: It is not permissible to enable the function "n < nx hysteresis and filtering" (p9301.16) in conjunction with the function "Extended functions without selection" (p9801.5)

Solution and Safe First Checks

  1. Correct the parameter value.

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Siemens error codes

Source: the Zeror.ai industrial fault database and Siemens technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.

Siemens F30681 · Zeror.ai