Zeror.ai Error Codes Siemens F30683

Siemens F30683

Brand: SiemensModel: SINAMICS G120 CU250S2Error code: F30683

What the Fault Means

Fault: SI Motion P2: SLS enable missing

Likely causes

  • The safety-relevant function "SLS" is not enabled in p9301 although other safety-relevant monitoring functions are enabled
  • Note: This message does not result in a safety stop response.

Solution and Safe First Checks

  1. Enable the function "SLS" (p9301.0) and carry out a POWER ON.

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Siemens error codes

Source: the Zeror.ai industrial fault database and Siemens technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.