Zeror.ai Error Codes Siemens F30692

Siemens F30692

Brand: SiemensModel: SINAMICS G120 CU250S2Error code: F30692

What the Fault Means

Fault: SI Motion P2: Parameter value not permitted for encoderless

Likely causes

  • For encoderless motion monitoring functions, the parameter cannot be parameterized with this value
  • Note: This message does not result in a safety stop response
  • Fault value (r0949, interpret decimal): Parameter number with the incorrect value
  • See also: p9301 (SI Motion enable safety functions (processor 2))

Solution and Safe First Checks

  1. Correct the parameter specified in the fault value.

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Siemens error codes

Source: the Zeror.ai industrial fault database and Siemens technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.

Siemens F30692 · Zeror.ai