Brand: SiemensModel: SINAMICS G120 CU250S2Error code: F35895

What the Fault Means

Fault: TM DRIVE-CLiQ (CU): Alternating cyclic data transfer error

Likely causes

  • A DRIVE-CLiQ communication error has occurred from the Terminal Module involved (TM) to the Control Unit
  • Fault cause: 11 (= 0B hex): Synchronization error during alternating cyclic data transfer
  • Note regarding the message value: The individual information is coded as follows in the message value (r0949/r2124): 0000yyxx hex: yy = component number, xx = error cause

Solution and Safe First Checks

  1. Carry out a POWER ON.

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.