Inovance E002.1

Marca: InovanceModelo: MD520 VFDCódigo de error: E002.1

Qué Significa el Fallo

Hardware overcurrent

Causas probables

  • Output grounding
  • Inter-phase short-circuit
  • No parameter auto-tuning in vector control mode
  • Encoder interference or wire breakage
  • Output phase loss
  • Current detection exception
  • V/f control acceleration/deceleration time too short
  • Encoder phase sequence error
  • Model setting error

Solución y Primeras Comprobaciones Seguras

  1. Check for output ground points and measure ground impedance by segment using a megohmmeter
  2. Check whether output side is short circuited
  3. Set motor parameters correctly and perform auto-tuning again
  4. Check encoder cable connection and grounding
  5. Check cables are properly connected
  6. Contact after-sales service
  7. Enable overcurrent suppression; increase acceleration/deceleration time
  8. Change encoder direction if opposite to motor direction
  9. Set AC drive model correctly (FF-01)