Siemens A01485

Marca: SiemensModelo: SINAMICS G120 CU250S2Código de error: A01485

Qué Significa el Fallo

Alarm: Topology: Controller Extension not inserted

Causas probables

  • The topology comparison has detected a Control Extension (CX32) missing in the actual topology with respect to the target topology
  • Alarm value (r2124, interpret hexadecimal): ddccbbaa hex: dd = connection number (%4) cc = component number (%3) bb = component class (% 2) aa = component number of the component that has not been inserted (% 1) Note: The component is described in dd, cc and bb, where the component has not been inserted
  • Component class and connection number are described in F01375.

Solución y Primeras Comprobaciones Seguras

  1. insert the components involved at the right connection (correct the actual topology).
  2. adapt the project/parameterization in the commissioning software (correct the target topology).
  3. check the 24 V supply voltage.
  4. check DRIVE-CLiQ cables for interruption and contact problems.
  5. check that the component is working properly.

Seguridad: no trabajes dentro del cuadro sin cortar la energía; si tienes dudas, consulta a un técnico cualificado.

Códigos de error Siemens relacionados

Fuente: la base de fallos industriales de Zeror.ai y la documentación técnica de Siemens. Esta página es informativa; en sistemas críticos sigue el manual del fabricante y el servicio autorizado.

Siemens A01485 · Zeror.ai