Siemens F03000

Marca: SiemensModelo: SINAMICS G120 CU250S2Código de error: F03000

Qué Significa el Fallo

Fault: NVRAM fault on action

Causas probables

  • A fault occurred during execution of action p7770 = 1 or 2 for the NVRAM data
  • Fault value (r0949, interpret hexadecimal): yyxx hex: yy = fault cause, xx = application ID yy = 1: The action p7770 = 1 is not supported by this version if Drive Control Chart (DCC) is activated for the drive object concerned
  • yy = 2: The data length of the specified application is not the same in the NVRAM and the backup
  • yy = 3: The data checksum in p7774 is not correct

Solución y Primeras Comprobaciones Seguras

  1. Perform the remedy according to the results of the troubleshooting.
  2. if necessary, start the action again.

Seguridad: no trabajes dentro del cuadro sin cortar la energía; si tienes dudas, consulta a un técnico cualificado.