Zeror.ai Hata Kodları Siemens A01389

Siemens A01389

Marka: SiemensModel: SINAMICS G120 CU250S2Hata kodu: A01389

Hatanın Anlamı

Alarm: Topology: Motor with DRIVE-CLiQ incorrectly inserted

Olası nedenler

  • The topology comparison has detected a motor with DRIVE-CLiQ in the actual topology that has been incorrectly inserted with respect to the target topology
  • Alarm value (r2124, interpret hexadecimal): ddccbbaa hex: dd = connection number (%4) cc = component number (%3) bb = component class (% 2) aa = component number of the incorrectly inserted component (% 1) Note: The component is described in dd, cc and bb, where the component involved is incorrectly inserted
  • Component class and connection number are described in F01375
  • The drive system is no longer booted

Çözüm ve Güvenli İlk Kontroller

  1. insert the components involved at the right connection (correct the actual topology).
  2. adapt the project/parameterization in the commissioning software (correct the target topology).
  3. automatically remove the topology error (p9904).

Güvenlik: Enerjiyi kesmeden pano içi işlem yapmayın; emin değilseniz yetkili teknisyene danışın.

İlgili Siemens hata kodları

Kaynak: Zeror.ai endüstriyel arıza veritabanı ve Siemens teknik dokümantasyonu. Bu sayfa bilgilendirme amaçlıdır; kritik sistemlerde üretici kılavuzunu ve yetkili servisi esas alın.