Zeror.ai Hata Kodları Siemens A02096

Siemens A02096

Marka: SiemensModel: SINAMICS G120 CU250S2Hata kodu: A02096

Hatanın Anlamı

Alarm: MTrace 0: cannot be saved

Olası nedenler

  • card is not inserted or is blocked by a mounted USB drive.
  • a second trace has been completed before the measurement results of the first trace were able to be saved.
  • writing the measurement result files to the card is blocked by the parameter save.
  • for instance, the file required for the data save operation was not able to be found.

Çözüm ve Güvenli İlk Kontroller

  1. insert or remove the memory card.
  2. use a larger memory card.
  3. configure a longer trace time or use an endless trace.
  4. avoid saving parameters while a multiple trace is running.
  5. check whether other functions are presently accessing measurement result files.

Güvenlik: Enerjiyi kesmeden pano içi işlem yapmayın; emin değilseniz yetkili teknisyene danışın.

İlgili Siemens hata kodları

Kaynak: Zeror.ai endüstriyel arıza veritabanı ve Siemens teknik dokümantasyonu. Bu sayfa bilgilendirme amaçlıdır; kritik sistemlerde üretici kılavuzunu ve yetkili servisi esas alın.

Siemens A02096 · Zeror.ai