Marka: SiemensModel: SINAMICS G120 CU250S2Hata kodu: F01360

Hatanın Anlamı

Fault: Topology: Actual topology not permissible

Olası nedenler

  • The detected actual topology is not permissible
  • Fault value (r0949, interpret hexadecimal): ccccbbaa hex: cccc = preliminary component number, bb = no significance, aa = fault cause aa = 01 hex = 1 dec: Too many components were detected at the Control Unit
  • A maximum of 199 components is permissible
  • aa = 02 hex = 2 dec: The component type of a component is not known

Çözüm ve Güvenli İlk Kontroller

  1. For fault cause = 1: Change the configuration
  2. Connect less than 199 components to the Control Unit
  3. For fault cause = 2: Remove the component with unknown component type
  4. For fault cause = 3, 4, 5: Establish a valid combination

Güvenlik: Enerjiyi kesmeden pano içi işlem yapmayın; emin değilseniz yetkili teknisyene danışın.

İlgili Siemens hata kodları

Kaynak: Zeror.ai endüstriyel arıza veritabanı ve Siemens teknik dokümantasyonu. Bu sayfa bilgilendirme amaçlıdır; kritik sistemlerde üretici kılavuzunu ve yetkili servisi esas alın.