Qué Significa el Fallo

mastering before switching off.

Causas probables

  • Three possible causes:
  • Back--up not available, e.g. the battery is not connected or the polarity
  • has been reversed.
  • The “DC UPS module 15” option is not available for every KPS, but battery
  • monitoring has been activated via $EXT_ACCU_MON=TRUE in $OPTION.DAT.
  • No DSE--IBS--C33 is installed.

Solución y Primeras Comprobaciones Seguras

  1. Before shutting the system down, back up the mastering to prevent loss
  2. of mastering. If the robot is then moved again before the system is shut
  3. down, then the mastering must be backed up again.

Seguridad: no trabajes dentro del cuadro sin cortar la energía; si tienes dudas, consulta a un técnico cualificado.