Siemens F01800

Marca: SiemensModelo: SINAMICS G120 CU250S2Código de error: F01800

Qué Significa el Fallo

Fault: DRIVE-CLiQ: Hardware/configuration error

Causas probables

  • A DRIVE-CLiQ connection fault has occurred
  • Fault value (r0949, interpret decimal): 100 ..
  • 107: Communication via DRIVE-CLiQ socket X100 ..
  • X107 has not been switched to cyclic operation

Solución y Primeras Comprobaciones Seguras

  1. ensure that the DRIVE-CLiQ components have the same firmware versions.
  2. avoid longer topologies for short current controller clock cycles.
  3. check the DRIVE-CLiQ cables at the Control Unit.
  4. remove any short-circuit for motors with DRIVE-CLiQ.
  5. carry out a POWER ON.
  6. check the electrical cabinet design and cable routing for EMC compliance

Seguridad: no trabajes dentro del cuadro sin cortar la energía; si tienes dudas, consulta a un técnico cualificado.

Códigos de error Siemens relacionados

Fuente: la base de fallos industriales de Zeror.ai y la documentación técnica de Siemens. Esta página es informativa; en sistemas críticos sigue el manual del fabricante y el servicio autorizado.