Zeror.ai Hata Kodları Siemens A01330

Siemens A01330

Marka: SiemensModel: SINAMICS G120 CU250S2Hata kodu: A01330

Hatanın Anlamı

Alarm: Topology: Quick commissioning not possible

Olası nedenler

  • bb = 01 hex = 1 dec: For a Motor Module, more than one motor with DRIVE-CLiQ was detected.
  • bb = 02 hex = 2 dec: For a motor with DRIVE-CLiQ, the DRIVE-CLiQ cable is not connected to a Motor Module.
  • bb = 01 hex = 1 dec: There is more than one master Control Unit.
  • bb = 02 hex = 2 dec: There is more than 1 infeed (8 for a parallel circuit configuration).
  • bb = 03 hex = 3 dec: There are more than 10 Motor Modules (8 for a parallel circuit configuration).
  • bb = 04 hex = 4 dec: There are more than 9 encoders.

Çözüm ve Güvenli İlk Kontroller

  1. adapt the output topology to the permissible requirements.
  2. carry out commissioning using the commissioning software.
  3. for motors with DRIVE-CLiQ, connect the power and DRIVE-CLiQ cable to the same Motor Module (Single Motor

Güvenlik: Enerjiyi kesmeden pano içi işlem yapmayın; emin değilseniz yetkili teknisyene danışın.

İlgili Siemens hata kodları

Kaynak: Zeror.ai endüstriyel arıza veritabanı ve Siemens teknik dokümantasyonu. Bu sayfa bilgilendirme amaçlıdır; kritik sistemlerde üretici kılavuzunu ve yetkili servisi esas alın.

Siemens A01330 · Zeror.ai