Siemens A01330

Бренд: SiemensМодель: SINAMICS G120 CU250S2Код ошибки: A01330

Что означает ошибка

Alarm: Topology: Quick commissioning not possible

Вероятные причины

  • bb = 01 hex = 1 dec: For a Motor Module, more than one motor with DRIVE-CLiQ was detected.
  • bb = 02 hex = 2 dec: For a motor with DRIVE-CLiQ, the DRIVE-CLiQ cable is not connected to a Motor Module.
  • bb = 01 hex = 1 dec: There is more than one master Control Unit.
  • bb = 02 hex = 2 dec: There is more than 1 infeed (8 for a parallel circuit configuration).
  • bb = 03 hex = 3 dec: There are more than 10 Motor Modules (8 for a parallel circuit configuration).
  • bb = 04 hex = 4 dec: There are more than 9 encoders.

Решение и первые безопасные проверки

  1. adapt the output topology to the permissible requirements.
  2. carry out commissioning using the commissioning software.
  3. for motors with DRIVE-CLiQ, connect the power and DRIVE-CLiQ cable to the same Motor Module (Single Motor

Безопасность: не работайте внутри шкафа без снятия напряжения; при сомнениях обратитесь к квалифицированному специалисту.

Похожие коды ошибок Siemens

Источник: промышленная база неисправностей Zeror.ai и техническая документация Siemens. Страница носит информационный характер; на критичных системах следуйте руководству производителя и авторизованной службе.

Siemens A01330 · Zeror.ai