Siemens F35896

Marka: SiemensModel: SINAMICS G120 CU250S2Hata kodu: F35896

Hatanın Anlamı

Fault: TM DRIVE-CLiQ (CU): Inconsistent component properties

Olası nedenler

  • The properties of the DRIVE-CLiQ component (Terminal Module), specified by the fault value, have changed in an incompatible fashion with respect to the properties when booted
  • One cause can be, e.g
  • that a DRIVE-CLiQ cable or DRIVE-CLiQ component has been replaced
  • Fault value (r0949, interpret decimal): Component number.

Çözüm ve Güvenli İlk Kontroller

  1. carry out a POWER ON.
  2. when a component is replaced, the same component type and if possible the same firmware version should be
  3. when a cable is replaced, only cables whose length is the same as or as close as possible to the length of the

Güvenlik: Enerjiyi kesmeden pano içi işlem yapmayın; emin değilseniz yetkili teknisyene danışın.

İlgili Siemens hata kodları

Kaynak: Zeror.ai endüstriyel arıza veritabanı ve Siemens teknik dokümantasyonu. Bu sayfa bilgilendirme amaçlıdır; kritik sistemlerde üretici kılavuzunu ve yetkili servisi esas alın.